Customer states problem started a couple of weeks previously with a crackling sound, thought it was one of their speakers at first but now got a burning smell when plugged it in so turned it off right away.
Diagnosing the Burned Zobel Network Resistor
Found R115 had burned up – part of zobel network (filtering and impedance stabilisation to the amp particularly for high frequencies and preventing HF oscillation). The cause of the original issue could have been an open circuit speaker under load or high output, and without the damping effect of the speaker, the amp may have become unstable and oscillate at supersonic frequencies. Possibly driven into hard clipping, the harmonics involved would also include very high frequency signals which the zobel resistor takes the brunt of energy from.

Removed in order to clean up – it had melted sleeving around the cap behind!

Replacement of resistor and testing
New resistor fitted:

The Zobel network capacitor was checked and was fine, so the amplifier was wired into a 1000W dummy load and monitored under load for any unexpected HF oscillation on the oscilloscope. It was behaving as expected and no other issues found, so was returned into service.
A few months after this service, this same amplifier returned to the bench for an accidental voltage selector blowup.